ACS-D
Series Digital Price-Computing Scale produced in our factory is a
multi-function measuring apparatus. It has the characteristics of accurate measure
,sensitivity, easy operation and steady function etc. It adops an advanced chip
computer and a sensor of superpresion with the reliable and steady performance
and durability.
Main qualifications and
functions
Specifications: 3kg/1g, 6kg/2g, 15kg/5g,30kg/5g, 30kg/10g,
Accuracy: Grade Ш Prevision(1/3000FS)
Set-tare: The set-tare weight is equal to the maximum weighing.
Over
weight: Alarm automatically when the weight is over 0.15% of the maximum.
Comprehensive function; it has the functions of
auto-tracking, set-zero, set-tareAccumulation, overweight alarm, for both AC and DC, battery alarm, auto-stop to save energy and
autosizing for the inside digital voltmeter etc.
Working power source:AC220V(-15%~+10%)50Hz DC 6V/4AH chargeable battery
Operation instruction
After opening box, please place the scale on the firm and
flat table and adjust it in the
horizontal position.
1. Insert the plug in the socket
and now the AC indicator is Turn on the power switch and
2. the electronic scale is doing
automatic check out. The indicator displays “0”after flashing “8”.
The weight window indicates the following:
Indicator condition
|
Meaning
|
Explaination
|
-----(at
the middle)
|
Display
long time,zero position is unsteady
|
Wind or wet
|
-------(at
the top)
|
Zero
position is too high
|
repair
|
-------(at
the underside)
|
Zero
position is too low
|
repair
|
Add
|
Accumulation condition
|
Normal display
|
---Lb—(alarm
voice)
|
The
battery voltage is low
5.4 ±0.1V
|
Charge battery
|
---OL--(alarm
voice)
|
overweight
|
move the subject
|
---NO—(alarm
voice)
|
PCB can’t work
|
repair
|
0
|
Saving energy
|
Normal display
|
3 weigh up subject
3.1.1 Don’t weigh up the subject
that is weigher than maximum. If the machine is overweigh, it will display
“OL” and hear of the alarm voice. User
should move the subject right now from the machine to avoid damaging it.
1. Push and Hold ‘CE’than Switch‘On’the Power Switch ‘on/off’(under the scale).
2. Display ‘F0’12345 Change Value ‘0’and ‘T’
3. Display ‘F1’Yes/No Change Value ‘0’and ‘T’
4. Display ‘F2’Yes/No Change Value ‘0’and ‘T’
5. Display ‘F3’Yes/No Change Value ‘0’and ‘T’
6. Display ‘F4’Nor/Set/Acs/Low Change Value ‘0’and ‘T’
7. Display ‘F5’No Change Value ‘0’and ‘T’
8. Display ‘F6’Yes/No ‘Sound Beep’ Change Value ‘0’and ‘T’
9. Display ‘F7’15/30 Change Value ‘0’and ‘T’
10.Display ‘F8’Yes/No Change Value ‘0’and ‘T’
11.Display ‘F9’Yes/No Change Value ‘0’and ‘T’
12.For Save Setting Push ‘MR’2x.
Calibration Prosedure
01 Push and Hold ‘0’than Switch ‘On’the CAL Switch Under the Scale
02 Display ‘C1’3/6/15/30 ‘Kg’ Change Value ‘0’and ‘T’
03 Display ‘C2’High/Low Change Value ‘0’and ‘T’
04 Display ‘C3’No/Yes Change Value ‘0’and ‘T’
05 Display ‘C4’Default
06 Display ‘C5’No/Yes Change Value ‘0’and ‘T’
07 For Save Setting Push ‘MR’then Display Save push ‘MR’
08 Input the Cal Load Value (3 until 30 kg)
09 Then Put the Load (Maximal Display Value 85999999)
10 Then Push the ‘MR’and Save.
11 If the load execed will Error Display
12 Change The Resistor to 20K Ohm in the circuit after Sign ‘+’ and Sign ‘–‘ loadcell.
13 Return to Cal Procedure